Examples

  • Small Power Transformer Applications
  • How we do design small power transformers

  • Inherently shortt-circuit-proof, potted safety power transformer up to 10VA, 50Hz

  • Not short-circuit-proof-low profile safety power transformeras,protected by a miniature fuse,18VA, 50Hz

  • Non-inherently shortt-circuit-proof,protected by thermal fuse, safety halogen lamp power transformer, 60VA, 50Hz

  • Rectifier safety power transformer for feed to voltage controllers of 5Vdc, 1Adc and 2x12Vdc,0.1Adc with RC-load

  • Three-phase rectifier, safety power transformer for 24Vdc, 80Adc supply with RC load

  • Low inrush current universal control power transformer, 800VA,50Hz

  • 8000VA power transformer for medical premises

  • 50kHz, 1200VA power transformer

  • 100kHz, flyback transformers for input voltage125-700Vdc and power up to 500W

  • 250kHz, 120W forward transformer with voltage controller, for input voltage range 200V to 350V

  • Low inrush current three phase universal autotransformer for 10kVA continuous output power

  • Motor starting three-phase power autotransformer for 100kVA continuous motor power

  • Non-short-circuit-proof, low profile safety transformers up to 42VA,in accordance with IEC 61558,protected by miniature fuse as per IEC 127

  • About the resonance transformer 1200W, 50kHz

  • Designing a simple 50kVA, 50Hz, 3 phase power transformer, in metric

  • Designing a 3 phase 500kVA, K-Factor=20, 3x480V /3x208V /120V (DYn),60Hz,power transformer,in USA unita

  • Designing a 3 phase, 50/60Hz rectifier transformer (YYD to suppress 5.and 7.current harmonics ) with 2 parallel connected bridge rectifiers for Udc=400V, Idc=1000A

  • Designing a 3 phase, 50/60Hz rectifier autotransformer (YZZ to suppress 5.and 7.current harmonics ) with 2 parallel connected bridge rectifiers for Udc=400V, Idc=1000A

  • Designing a 3 phase (Y0-Y0-Y12), 50Hz, high current rectifier transformer for Udc=12Vdc, Idc=30000Adc

  • Designing a 1600kVA, 35kV, 50Hz Distribution Oil Transformer

  • Designing a and 1600kVA, 35kV, 50Hz Distribution Oil Transforme and Oil Tank

  • Creatung Input to Design the Rectifier Transformers

  • Creating a 4 lines 3 phases net in a 3 lines 3 phases net using Zn transformer NEW

  • Designing a single phase, 10kVA, 50-2000Hz frequency converter transformer

  • Designing a single phase, 1kVA, 50/60Hz transformer with cooling channels

  • Designing a 3 phase,1MVA, 50Hz, "dry" distribution transformer 3x35kVA/3x400V

  • Designing a single phase,100VA, 50Hz, transformer for duty cycle operation mode 10seconds-ON, 10 minutes OFF

  • How we do design a toroidal power transformers

  • How we do design chokes an inductors

  • Designing motor Filter Chokes

  • Power Factor Correcton Chokes

  • Commutation Chokes

  • Smoothing Chokes

  • LC Filter Chokes

  • Current Compensated Chokes:One-Phase Common Mode Choke,Three-Phase Common Mode Choke, Drenage Chokes

  • Indirect water cooled 3 phase inverter choke, 0.5mH,600Arms, 60Hz

  • Motor Starting Chokes

  • Constant Current Transformer

  • Transformer UI-Design

  • Balancing 3 phase net wit a single phase Load

  • Rale's workshop on CWIEME 2008 in Chicago

    This Rale workshop approaches the design of transformers for a Transformer Manufacturer from point of view of a buyer and/or user of transformers. To demonstrate these applications, Rale selected about 20 design examples as follows:

  • Designing inherently short-circuit-proof, potted safety transformers 12V, 0.166A in accordance with IEC 61558
  • Designing inherently current limited, potted safety transformers 10V, 5A in accordance with UL 1585 Class 2
  • Designing inherently current limited single phase transformer 24V, 100A with integrated inductor
  • Designing high voltage ,potted transformers 10kV, 0.1A, 1500Hz
  • Designing mixed operation mode transformer, 230V/115V, 10A in autotransformer and 230V/115V, 10A galvanic separated connection
  • Designing three phase autotransformer, for 3x400V/3x380V, 10kVA output power and 25% one phase unsymmetrical load
  • Designing three phase, low inrush current universal autotransformer for 3x208V/120V, 50/60Hz, 9A
  • Designing rectifier transformer for battery charger 6Vdc, 40dc
  • Designing rectifier transformer for welding with 26Vdc, 200Adc
  • Designing the audio transformer for loudspeaker 25W, 16_Ohm
  • Designing flyback transformer for capacitor charger 10kVdc, 0.1 µF, 50W
  • Designing a 500 kVA, 60Hz, K-Factor, three phase dry transformer with cooling channels?
  • Designing a 3 phase, 50/60Hz rectifier transformer (YYD to supress 5. and 7. harmonics) with 2 parallel connected bridge rectifiers, for Udc = 400V and Idc = 1000A
  • Designing a 12Vdc, 30kAdc Rectifier Transformer
  • Designing a 1600kVA/35kVA, 50Hz Distribution Oil Transformer
  • Designing Water Cooled Inverter Filter Choke, 0.5mH, 600Arms, 60Hz
  • Power Factor Correction Chokes
  • Commutation Chokes
  • Smoothing Chokes
  • LC-Filter Chokes
  • Current Compensated Chokes
  • The concept is to assist the Transformer Manufacturers to incorporate transformer designs as an integral part their business and also for the Transformer Manufacturers to get a better overview about new applications that they could be easily integrated in their production using Rale's design software. For this reason Rale has included very powerful design guidelines, for instance relating to water cooling, high voltage spacing, etc.